AXN/ADC/405 Differential Ended ADC (5 kHz b/w) - 24 Analog Channels

flight test and monitoring family header
AXN/ADC/405 Differential Ended ADC (5 kHz b/w) - 24 Analog Channels
Product Sheet
Product Sheet

The AXN/ADC/405 is used to condition and digitize up to 24 analog differential-ended channels. Single-ended configurations are possible by enabling programmable pull-down resistors on any of the negative inputs.

Features

  • 24 differential ended input channels
  • Ordering input range from ±100 mV to ±40V
  • High accuracy (0.01% FSR typical)
  • High input resistance (>1 MΩ) when on/off for /100M, /1V, and /10V variants
  • 16-bit simultaneous sampling with three configurable output streams on each channel
  • User defined linearization and compensation for errors in the entire measurement chain

Applications

  • Differential voltage measurement
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

AXN/ADC/405 Differential Ended ADC (5 kHz b/w) - 24 Analog Channels

The AXN/ADC/405 is used to condition and digitize up to 24 analog differential-ended channels. Single-ended configurations are possible by enabling programmable pull-down resistors on any of the negative inputs.

At the heart of the AXN/ADC/405 is a hard-wired state machine that oversamples all channels at a rate between 40 ksps and 80 ksps and digitally filters any noise above the user-programmable cutoff frequency. This is achieved using cascaded, 15-tap FIR filters with output rate decimation, followed by a final FIR or IIR filter. If IIR filtering mode is selected, the last digital filter in the filtering chain is an 8th or 16th order (selectable) Butterworth filter. If FIR mode is selected, the last digital filter in the filtering chain is a 49-tap Kaiser window, Beta 6 filter.

There are three independently configurable output streams per channel, allowing different sample rate, cutoff, and filter type to be selected for each output stream.

All signals are sampled simultaneously. When several channels are sampled at different sampling rates, at the start of an acquisition cycle all channels are aligned.

 

Aerospace Instrumentation Brochure

Modern aerospace instrumentation systems can be highly complex, and it can be difficult to know how to meet program needs. It’s not unusual for requirements to change during a campaign and cause significant delays, and data must be captured reliably no matter what – otherwise expensive additional flights will be needed or months of program data could be lost. Read our brochure to learn how you can reduce your risk with commercial off-the-shelf (COTS) solutions. 

Read the Brochure
 

Axon Data Acquisition Unit (DAU) Product Family Brochure

For airborne applications where reliability and size, weight, and power (SWaP) are critical, the Curtiss-Wright Axon family of data acquisition units (DAU) are ready to take flight. Designed leveraging our decades of experience as a trusted, proven leader, Axons are future-proof, SWaP-optimized, and available in a variety of flexible configurations to meet your exact program requirements.